Window Nighttime U-Values: A Comparison Between Computer Calculations and MoWiTT Measurements
Publication Type
Journal Article
Authors
Abstract
For six windows the U-values measured with the MoWiTT under field conditions are compared with detailed U-value calculations for the same conditions using the programs WINDOW and ANSYS. There is good agreement between measurements and calculations.
Journal
ASHRAE Transactions
Volume
96
Year of Publication
1990
Organization
Building Technologies Department, Building Technology and Urban Systems Division, Windows and Envelope Materials