Boundary Conditions Changed from Comprehensive to Simplified

Boundary Conditions Changed from Comprehensive to Simplified

Software/Versions Affected:

  • THERM›6
  • THERM›7

If a Boundary Condition is initially defined with the Model = Comprehensive in the Boundary Condition Library and applied to a cross section surface, an then is later changed to Model = Simplified in the Boundary Condition Library, if the applied boundary condition is "clicked on", the Radiation model will still be set to "AutoEnclosure" even though it shouldn't be. The solution is to make a completely new Boundary Condition with the Model = Simplified, rather than taking one that was originally defined with the Model = Comprehensive.

Boundary Condition is originally defined as Model = Comprehensive
Boundary Condition is changed to Model = Simplified
When a boundary condition segment is clicked on, the Radiation Model is still set to AutoEnclosure, even though it shouldn't be.