WINDOW 5.2 (5.2.17)
Version Fixes:
Return to WINDOW 5.2 Knowledge Base
Detailed List of Recent Version Fixes:
WINDOW 5.2.17 Fixes:
| Bug # | Description |
| 753 | Single-band angular calculations are now working correctly for glazing systems |
| 754 | Added ability to export glass spectral data to W4.1 format |
| 750 | Fixed the divider tabbing problem in the Window Library |
| 744 | ID's greater than 33,000 now should work for all libraries. Note that as a result, changes were made to the W4 glazing system export to keep it compatible. |
| 740 | Angular data is now calculated correctly in the Window Library detailed report |
| 741 | Added 3 decimal output for SCc, SHGCc, and VTc for Glazing Systems in Window Library detailed report |
| 743 | optics standards files that don't have color or UV methods generate warnings, not errors and set those values to N/A |
| 745 | no longer forgetting the path for the Optics DB's |
| 747 | better error trapping when accidentally opening an optics db as a W5 db |
| 748 | energy plus reports working properly for windows with 2 glazing systems |
| 742 | eliminated a memory leak related to Therm temperature profile data |
| 755 | workaround for occasional error in optics for 0 transmittance layers like 90 degree angles... |
| 756 | additional memory leak fixed from repeated open and closing of databases |
| 757 | relative pathnames no longer cause IR image to fail |
| 758 | minor format changes to window detailed report |
| 759 | opening a recent file no longer causes the current file from not appearing on the recent file list |
| 760 | possible fix for XP proportional font report problem. added a new INI file entry called ReportFontName, e.g. ReportFontName=Courier New can be used to change the report font this may not be needed to fix the XP problem... |
| 761 | when changing Nominal Thickness preference, all results (both window and glazing system are invalidated) as a result, the glazing system library is no longer slow (this used to be because it always recalculated overall thickness in case nominal had changed...) |
| 762 | occasional non-responsive glazing system layer spin button fixed (this happened when you changed another field first (e.g. comment) then directly hit the spin button. |
| 763 | added RHG to the GlazSysList table. |
WINDOW 5.2.12 Fixes:
| Bug # | Description |
| 739 | Implemented the ASTM SI-10 conversion units for converting from SI (WINDOW5's native units) to IP. |
WINDOW 5.2.11 Fixes:
| Bug # | Description |
| 738 | Fixed problem with calculating CR for dividers. Program now implements the same strategy for horizontal and vertical divider CR calculation as for other horizontal and vertical profiles |
WINDOW 5.2.10 Fixes:
| Bug # | Description |
| 737 | Fixed problem where program was crashing when importing THERM files |
WINDOW 5.2.09 Fixes:
| Bug # | Description |
| 736 | Fixed problem where SHGC would show N/A for some entries |
WINDOW 5.2.08 Fixes:
(INTERNAL NFRC SOFTWARE TASK GROUP REVIEW VERSION DISTRIBUTED)
| Bug # | Description |
| 734 | Fixed typo in the new preferences option for not showing CR report |
| 735 | In Window Library Detailed View, tilt limits changed to allow 20 and 90 as entries for CR calcs, message text improved |
WINDOW 5.2.07 Fixes:
| Bug # | Description |
| 729 | Fixed bug where program put up message " one of the glass layers does not have spectral data" for all glazing systems, even those that do have spectral data. |
| 732 | Added to Preferences the ability to turn off the "No CR results" when calc'ing a Window record (this can happen when the user only wants to calculate U-value and doesn't care about CR and the message comes up every time) |
| 733 | Fixed problem where a calculation would work in Window Library List view, but in Detailed View and the results will be "?". This would be caused by a multi-lite glazing system. |
WINDOW 5.2.06 Fixes:
| Bug # | Description | ||||||
| 730 | Tilted products
handled properly for CI:
Frame library indicates whether CI data is for CR sim (default if available) or U-factor results. CI detail gives the frame location name rather than 1, 2, 3... |
WINDOW 5.2.05 Fixes:
| Bug # | Description |
| 719 | Fixed bug which caused "Division by zero" in dialog box labeled "Optics5 DLL error in CIE Dominant Wavelength calc" in Window Library. This was due to a problem with angular calculations for EnergyPlus, DOE2 report, and Angular Data button in Glazing System Library |
| 724 | Changed references to "Optics5 database" to "IGDB" |
| 727 | Added more wrapping in reports (for Glazing System Name and Glass names because IGDB is going to long names rather than keeping the 8.5 format) |
WINDOW 5.2.04 Fixes:
(INTERNAL NFRC SOFTWARE TASK GROUP REVIEW VERSION DISTRIBUTED)
| Bug # | Description |
| 717 | In the Window Library Detailed View, the Delete key no longer deletes records. |
| 723 | Fixed bug where a checksum of 0 would result in a # |
| 725 | Fixed bug where clicking on the columns for "Cond" and "Database Version" in the Glass Library import screen would crash the program |
| 728 | Fixed bug where results for windows with 2 vision areas with different glazing systems could be incorrect. |
WINDOW 5.2.03 Fixes:
| Bug # | Description |
| 622 | Add Edge CI Overall and Frame CI Overall to the List View of the Frame Library |
| 715 | In DOE2 report, added name of spectral data file if one is used |
| 716 | Added message in the Glass Layer at the time a Glass record is copied, and in the Glazing System and Window Libraries at Calc time, if there is a Glass Layer being created or used in a calculation that does not have spectral data associated with it. |
| 718 | Fixed weird left and right justification of text and numbers in List View |
| 719 | Clean up deleted glazing system layers in the underlying database when the program is closed. Before, they were kept in the database and just not referenced, now that is cleaned up. |
| 720 | More rigorous checking of updated Frame and Divider libraries when doing a calculation of multiple records from the Window Library List View. Now that calculation should always produce the same result as a calculation from the Window Library Detailed View |
| 722 | Add SC to the Window Library Report (Detailed and List) as well as Glazing System Library (Detailed and List). |
WINDOW 5.2.02 Fixes:
(INTERNAL NFRC SOFTWARE TASK GROUP REVIEW VERSION DISTRIBUTED)
| Bug # | Description |
| 711 | Added Reports for the List View of all Libraries. Added a choice for Text or RTF as format choices for saving the reports. |
| 714 | Added a Color Properties tab in the Glazing System Library Detailed view which displays L*a*b*, purity and dominant wavelength |
| 715 | DOE-2 files now include glass name if they have spectral data |
| 716 | A warning is displayed when copying a glass record or calc'ing a record (in the Glazing System Library) without spectral data |
WINDOW 5.2.01 Fixes:
| Bug # | Description |
| 689 | Fixed the temperature map display |
| 705 | Fixed problem where program didn't remember the All Records or Selected Records choice in the Export dialog box from the Window Library |
| 706 | Program would misbehave (gillions of weird records) when there were no records in the Window Library |
| 708 | Dewpoint temperature in the CI Details view now displays in the units (SI or IP) that are currently selected in the program (used to only display in SI) |
| 709 | Added export function for SHGC0/1 and VT0/1 Details box -- exports to CSV file for import into spreadsheet program |
| 712 | Copy and New now prompt for saving the current record before making the new record |
| 713 | Implement keyboard shortcuts (Alt-letter) for most of the buttons on the Detailed view of each library |
WINDOW 5.1.01 Fixes:
| Bug # | Description |
| 680 | In Glazing System Library List View, Relative Heat Gain is now displayed in the units set in the program (SI or IP) and the units are displayed in the header of the column |
| 691 | Fixed the Gas Data line in the EnergyPlus report which was too long |
| 692 | Program now reports the glass layer data to 3 decimal places in the EnergyPlus file |
| 693 | Now when a new record is added to the Environmental Conditions Library, it immediately shows up in the Glazing System Library pulldown list for Environmental Conditions |
| 699 | The Save button on the Environmental Conditions Library now works |
WINDOW 5.0.90 Fixes:
| Bug # | Description |
| 597 | fixes problem where custom sizes in Window Library sometimes gave wrong results |
| 653 | fixes CSV export problem |
WINDOW 5.0.89 Fixes:
| Bug # | Description |
| 649 | added Update button in Frame Library to rebrowse to THERM files to get updated results |
| 573 | fixes bug where Optics user database records are imported as protected |
WINDOW 5.0.88 Fixes:
| Bug # | Description |
| 640 | Added a Details button to SHGC and VT on the Window Library detailed view for SHGC 0 & 1 and VT 0 & 1 for NFRC simulations |
| 643 | fixes crash when WINDOW can't find Optics5 database |
| 646 | changed CI to CR in Window Library per NFRC standards |
| 647 | fixes crash switching databases |
| 650 | fixes crash in exporting records |
| 651 | added a value in Preferences that controls the absorptance of the THERM file when importing into the Frame Library. The default value for the preference will be 0.3, but the user can change it to any value. |
| 589 | fixes WINDOW 4.1 report problems with some values in IP units |
WINDOW 5.0.87 Fixes:
| Bug # | Description |
| 637 | fixes crash in temperature map |
| 481 | added feature to import and export records between databases from any of the libraries |
| 636 | fixes bug in Energy
Plus file where the following line was run together:
GLAZING SYSTEM OPTICAL DATAAngle 0 10 20 30 40 50 it is now properly written as two lines: GLAZING SYSTEM OPTICAL DATA |
WINDOW 5.0.85 Fixes:
| Bug # | Description |
| 629 | fixes problem of a negative keff with a triple glazed window using SHGC (summer) environmental conditions for U-factor calculations |
WINDOW 5.0.84 Fixes:
| Bug # | Description |
| 626 | CI calculations fixed for jambs with CI -- program uses the temperatures from the U-factor calculations if there are no CI temperatures from THERM |
WINDOW 5.0.83 Fixes:
| Bug # | Description |
| 242 | units are displayed on status bar |
| 444 | when all records are deleted and you go to detail edit, a default record is created. |
| 584 | doe-2 output works for multiple records |
| 592 | edits made to user defined records in the Glass Library are kept, program asks to save when leaving the record |
| 604 | added more space for filename in import dialog, so filenames and paths don't overwrite each other |
| 609 | greatly increased the limit for number of files that can be imported at once (4K bytes worth of names...) |
| 613 | toolbar button added to change units |
| 616 | saving the mdb file to the name of the currently open file does not crash the program |
| 617 | temperature map is disabled if temperature profile data is not available |
| 618 | data entry allowed for window edit screen |
WINDOW 5.0.82 Fixes:
| Bug # | Description |
| 612 | Program crashed when importing THERM files |
| 608 | Divider Library copy didn't work properly |
WINDOW 5.0.81 Fixes:
| Bug # | Description | ||||||||
| 510 | In Frame and Divider libraries, the old import order was case sensitive alphabetic...changed this to case insensitive, so the files should import in a more normal alpha-numeric order. | ||||||||
| 590 | unit system (IP or SI) is remembered between sessions | ||||||||
| 600 | When importing a THERM
file in the Frame or Divider Libraries, w5 looks for SHGC Exterior tag for
wetted length. If it does not exist,
the Interior Frame tag is used. This is actually an implementation of ISO
15099 from THERM -- it is necessary to tag the exterior frame components
in THERM to a U-factor tag of "SHGC Exterior". If it is not
tagged, a message will appear at import time saying:
"Can't find the SHGC Exterior tag. Using Frame tag instead". This might be a good topic to discuss at the NFRC Snowbird meeting. |
||||||||
| 602 | In the Window Library
Detail View, a keyboard strategy for defining a window implemented. For
this to work, you need to initially have a component on the window graphic
selected (you do not have to be on the Frame Name field):
|
||||||||
| 603 | SHGC0 and SHGC1 calculations added on the Window Library Details screen under Total Product Results. They are always calculated and can be exported with the other Window Library information into a comma separated file which can be imported into a spreadsheet | ||||||||
| 606 | crash after display precision change is fixed. | ||||||||
| 607 | automatically updates from the previous database version which was shipped with WINDOW 5.02 Beta (v 5.0.79). When opening the program that points to a database from the previous version, the program will display a message saying the database has been updated. The update adds 2 fields to the Window Library table, which are the SHGC0 and SHGC1 results. |