COMFEN 4.0
(4.0.47 -- November 7, 2011)
Release Notes
Updated:
11/07/11
History of COMFEN 3.1 Releases
New Features
Glazed Wall Assembly In addition to modeling individual windows, COMFEN now has the capability of
modeling "Glazed Wall Assemblies" which allow you to specify the number of
horizontal and vertical framing members, as well as their spacing, and the
program automatically generates the facade.
Click here for more details.
Material Library
COMFEN now has a Material
Library, which can be used in the Wall Construction and Spandrel
Libraries. See the User Manual for more
details.
Wall Library
COMFEN now has a Wall
Library which can be used to build up layers from the Material Library
to define a wall. See the User Manual for
more details.
Spandrel Library
COMFEN now has a Spandrel
Library which can be used to build up layers from the Material Library
to define a spandrel, including glass and glazing systems as the
outer-most layers. See the User Manual for
more details.
Radiance Renderings --
Automatic Generation of BSDF Files
It is no longer necessary to generate WINDOW 6 BSDF files "by hand"
for the Radiance renderings. COMFEN now automatically generates those
when it creates the renderings.
CSV Import Additions
Shading Systems and Glazed Wall Assembly components have been added
to the CSV Import file options.
Click here for a
detailed description of how to create and use the CSV Import file
features. There are two different formats for CSV files:
Double Click Adds Records
to Glazing System Library
In addition to dragging Glass and Gas layers to a Glazing System, double
clicking on the desired record will cause it to be added to the end of
the Glazing System Construction list.
Hourly Report Option
There is now an option for specifying a series of hourly reports to be
generated. See the User Manual for more
details.
Economizer Added
An economizer mode has been added to the default Packaged Single Zone
HVAC system, and the Economizer controls can be set in the Scenario Edit
screen, under the Environment section.
Program Changes
Hospital Building Type
Removed
Because of the complicated HVAC modeling assumptions for the Hospital
building type, we have removed it from the program for now. We will add
it back in when we have resolved the modeling issues.
Energy Plus Version 6.0
COMFEN has been updated to be using version 6.0 of Energy Plus
Peak Demand Calculation
The Peak Demand Calculation is now based on the co-incident peak demand
for gas and electricity separately. The displayed results are now
side-by-side bars rather than stacked bars. The program now ALWAYS
includes the equipment (plug load) energy consumption in the peak demand
calculations (there is no longer an option in Preferences/Energy Plus to
include it or not).
Glass Library Updated to
IGDB 19.0
The Glass Library in this version of COMFEN has been updated to the IGDB
version 19.0
Site-To-Source Multiplier
Default Changed to 1.0
The default Site-To-Source Multiplier in Preferences / Energy Plus has
been changed from 3.18 to 1.0, as many users wanted to see the actual
Site energy consumption for electricity rather than source. If you want
to use a value other than 1.0, change it in Preferences / Energy Plus.
Frame Modeling for Frame
U-values < or =
6.2 Watts/m2-K (1.1 Btu/h-ft2-F)
Right now, COMFEN has a maximum Frame U-factor value of 1.1 Btu/h-ft2-F.
This is because of limitations in the Energy Plus calculation engine for
highly conductive frames. We are working with the Energy Plus
Development Team to resolve this issue, but it may be several months
before a fix will be implemented in the Energy Plus program.
Fixed Bugs
If you find bugs, or if you
think these have not been fixed, please do not hesitate to send an email to
RDMitchell@lbl.gov to report your
findings. Getting feedback from users is how we improve the program.
Fixed in 4.0.47
GWA Input Screen
Scrollbars For low resolution monitors (such as on laptops) the
Glazed Wall Assembly input screen now has scroll bars so that you can
get to the Done and Cancel buttons at the bottom. This has been fixed in
4.0.47
Radiance BSDF Problem
with Windows XP Operating System
There was a problem generating the BSDF files for Radiance on the
Windowx XP operating system, which has been fixed with version 4.0.47
Fixed in 4.0.45
Daylight Illuminance Map
The dimensions of the room/zone now display correctly on the Comparison
/ Summary screen.
Scroll Bar Slider on
Shading System Library
In the Project Browser Libraries tab (left side of the screen) the
Scroll Bar slider did not work. This has been fixed.
Overhang or Fin Does Not
Display
If the Overhang or Fin was outside the exterior facade wall, it would
not be displayed. This has been fixed.
Corrected CSV Export
Units
There were bugs associated with the units being displayed in the CSV
Export files. This has been fixed.
|